Dear international teams!
Here are the results of electrical energy assignment!
Team | Assignment 1 (max 25 points) | Assignment 2 (max 30 points) | Assignment 3 (max 45 points) | Total |
SchwerinGoethe1 | 25 | 30 | 45 | 100 |
SchwerinGoethe2 | 18 | 24 | 18 | 60 |
FEEDBACK
SchwerinGoethe1:
Part 1: Epot assessment correct.
Part 2: Epot assessment correct, the reservoir is large enough and this will have even 258 MWh surplus stored.
Part 3: the area assessment is correct.
SchwerinGoethe2:
Part 1: Water level rise is to be 1m, but 15m is the total height difference. So here the height 14m is double-used in calculation. Correct answer would be Epot ~ 410 MWh.
Part 2: a bit confusing, but in essence the extracted energy found with correct approach.
Part 3: 60 h total energy demand specified OK, but confusion is in 100%-75%-13% proposal.